Households

Up to 6,2m3 per day

Households, restaurants, cafes

Commercial

Up to 19,2m3 per day

Hotels, pensions, residential and office buildings

Industry

Up to 18,1m3 per day

Pure water for industry

Households - Sea water treatment

  • The water quality exceeds EU and the World Health Organization regulations.

  • The unit is equipped with a mineral content adjustment as a standard feature. This results in further water quality improvement and better taste in comparison to similar units missing this functionality.

  • Advanced electronic control of the unit automatically switches off the entire unit in case of a failure in any of the pump. This minimizes damage to the pump.

  • In case of a excessive pressure, the unit automatically lowers the working pressure. This prevents damage to the membrane or high pressure pump.

  • The unit has very low energy consumption that positively improves the long term operating costs.

  • The technology was developed with the stress on reliability in the difficult working environment and low maintenance. Only high quality components are selected to satisfy our customer needs. The modularity of the unit allows easy and simple repair and exchange any of its part.

     

Standard line

Technical specification: 

Type

Output 2)

Dimensions (hxwxd)

Weight 

Power consumption  3)

Scylla 60

1560 l/day

65x132x60cm

86kg

1,5kWh

Scylla 120

3110 l/day

65x132x60cm

94kg

1,5kWh

Scylla 180

4670 l/day

65x132x60cm

102kg

1,5kWh

Scylla 240

6210 l/day

65x132x60cm

110kg

1,5kWh

 

Standard-L line

Technical specification: 

Type

Output 2)

Dimensions (hxwxd)

Weight 

Power consuption  3)

Scylla 120L

3110 l/day

65x231x60cm

94kg

1,5kWh

Scylla 240L

6210 l/day

65x231x60cm

110kg

1,5kWh

Notes:
1) The daily water production can vary +/- 20% depending on the quality of the sea water and temperature.
2) The water production is calculated for 35 000 ppm NaCl, 25°C und 55 bar.
3) The power consumption is calculated for 55 bar.
4) The average consumption is about 150 l/day. This number represents the average daily consumption of drinking and supply water.

 

Basic line

This line is missing the feeding pump. This simple unit can be connected to the existing sea water supply. It requires at least 2 bar of the feeding water pressure. 

Technical specifications:

Type

Output 3)

Dimensions (hxwxd)

Weight 

Power consumption 4)

Scylla 60B

1560 l/day

65x132x60cm

82kg

1,1kWh

Scylla 120B

3110 l/day

65x132x60cm

90kg

1,1kWh

Scylla 180B

4670 l/day

65x132x60cm

98kg

1,1kWh

Scylla 240B

6210 l/day

65x132x60cm

106kg

1,1kWh

Notes:
1) The daily water production can vary +/- 20% depending on the quality of the sea water and temperature.
2) The unit requires at least 2 bar at the sea water inlet.
3) The water production is calculated for 35 000 ppm NaCl, 25°C und 55 bar.
4) The power consumption is calculated for 55 bar.
5) The average consumption is about 150 l/day. This number represents the average daily consumption of drinking and supply water.